BITSCOPE store USB BitScope 100 ( BS100U )

The correct appearance of this website is only visible in graphical browsers that support web standards. We try to ensure our content is accessible to any browser but we recommend you upgrade your web browser if you can.
USB BitScope 100

USB BitScope 100

Product Summary
Order Code BS100U
Description 100 MHz x 9 channel (2 analog or 8 logic + 1 analog) 40 MS/s, 128 kB buffer, DSP waveform generator (optional).
Comment USB, Isolated, Low Power.
Price USD (US Dollar) $ 575.00
Net Weight 633 g
Product Information

BS100 is a high performance isolated USB Mixed Signal Oscilloscope for your PC or notebook.

It combines a dual channel digital storage oscilloscope, 8 channel logic analyzer and optional DSP waveform generator with a real-time spectrum analyzer and data recorder in one small unit, fully opto-isolated from the PC to which it is connected.

Feature Specification
Analog Inputs [1] 4 (2 x BNC + 2 x POD)
Analog Bandwidth [2] 100 MHz
Analog Channels 2 (dual A/D converters)
Logic Channels 8 (via POD connector)
Input Impedance 1M/20 pF (BNC), 100K/5 pF (POD)
Input Voltage Range (+/-) 50 mV (x10 prescale) to 1kV (x100 probe)
Vertical Scaling (DSO) 500 uV/Div to 500 V/Div (x100 probe)
Timebase Range (DSO) 50 nS/Div to 1 S/Div
Post-Trigger Delay (DSO) 8 uS to 2 hours (programmable)
Input Prescaler [3] x10 and GND reference
Analog Sensitivity 2mV to 40mV (x1, no prescale enabled)
Maximum Sensitivity [4] 300 uV (Time), 70uV (Freq), 10uV (Mean)
Hardware Sample Rates 15kS/s to 40MS/s (58 rates)
Channel Buffers (max) 64 kS x 2 (analog) plus 64 kS x 8 (logic)
Streaming Sample Rates [5] 1S/s to 50kS/s (continuous)
Real-Time Sample Rates [6] 1kS/s to 40MS/s (per buffer)
Equivalent-Time Rates [7] 10MS/s to 2GS/s (per buffer)
Resolution (Converter) TLC5540 8 bit converter with 6.8 to 7.6 ENOB
Maximum Resolution [8] 11.5 ENOB
Glitch Capture>(min) 25 nS
External Trigger Bus YES (logic channels may also be used)
BitScope Digital Trigger 8 bit combinatorial on logic or A/D outputs.
High Speed Analog Trigger YES (on any analog input)
DSP Waveform Generator [9] OPTIONAL (via BNC-B and/or POD)
Analog Interface 2 x BNC and 2 x POD
Logic Interface 1 x IDC-26 (inc. logic, analog, data and power)
Display Frame Rate (max) 50 Hz (single channel), 25 Hz (dual or mixed)
Data Upload Speed (max) 1,200 kb/s (Raw Data), 450 kb/s (Enhanced)
PC Host Interface Opto-Isolated USB 2.0 (USB 1.1 compatible)
Included PC Software BitScope DSO Virtual Instrument Application
Power Requirement [10] 12 VDC @ 500 mA (max), 2.5mm CP
Quiescent Power [11] 50 uA on USB (low power mode)
Operating Temperature 0ºC to 50ºC
Storage Temperature -20°C to +60°C
Size (WxHxD) 150x40x105 mm
[1] Analog capture for each channel is selectable from BNC or POD individually.
[2] Input bandwidth refers to the bandwidth of the analog input circuitry and the compensated A/D converter in all but the most sensitive input range.
[3] User selectable analog input prescaler with x10 gain for use with low level signals or when input bandwidth limiting is required.
[4] Minimum measurable peak-to-peak sinusoidal waveform voltage when both resolution enhancement and input multiplier are enabled, when viewed as a waveform (Time) or viewed as a spectrum (Freq) and the minimum measurable average DC voltage (Mean).
[5] Streaming capture sample rates for data logging and transient recorder applications.
[6] Real-Time (Nyquist Limited) sample rates (captured per frame).
[7] Equivalent-Time (not Nyquist limited) sample rates sample rates (captured per frame). Applies to the capture of periodic and many common RF signals.
[8] Specifies the maximum effective number of bits (ENOB) achieveable with resolution enhancement enabled.
[9] Optional DSP module (DWG100) supports concurrent waveform generation (via BNC-B or POD 26) with dual channel waveform and spectrum capture and display.
[10] Includes UPP-02 Universal AC adaptor and US power cable as standard.
[11] Power requirement in standby mode. Useful when run on battery power.
E&OE 

Analog and logic probes are sold seperately.